Pipe Size Chart and Finder
Tables last checked October 8, 2026.
A typical 1/2 inch PVC Sch 40 pipe measures 0.840 inch across the outside and 0.622 inch inside.
1. What size is my pipe?
Measure the outside. A string wrapped once around the pipe, then laid on a tape measure, works when you have no caliper.
2. Look up a size
- Outside diameter (average)0.840" (21.3 mm)
- Inside diameter (OD minus two minimum walls)0.622" (15.8 mm)
- Wall thickness (minimum)0.109" (2.8 mm)
- Max working pressure, 73°F600 psi
- Water inside, per 10 feet0.16 gal
- Size systemIron pipe size: same OD as steel pipe
- Made toASTM D1785
Maximum working pressure at 73°F (Charlotte Pipe). Charlotte rates its Schedule 40 pressure pipe for systems where the operating temperature will not exceed 140°F.
Other 1/2" pipe, same nominal size:
| Pipe | OD | ID | Inside area vs this one |
|---|---|---|---|
| PVC Sch 80 | 0.840" | 0.546" | 77% |
| Steel Sch 40 | 0.840" | 0.622" | 100% |
| Copper K | 0.625" | 0.527" | 72% |
| Copper L | 0.625" | 0.545" | 77% |
| Copper M | 0.625" | 0.569" | 84% |
| PEX | 0.625" | 0.475" | 58% |
| CPVC CTS | 0.625" | 0.489" | 62% |
Fittings for 1/2" PVC Sch 40:
- Buy 1/2" PVC fittings. Sockets are tapered to the 0.840" outside diameter: they open slightly larger and tighten to about the OD at the bottom (Charlotte Pipe's belled-end 1/2" socket: 0.844" to 0.852" at the entrance, 0.832" to 0.840" at the bottom).
- Schedule 40 and 80 pipe of the same size share this outside diameter, so either fits 1/2" socket fittings. Join with primer and PVC cement; Charlotte Pipe's Schedule 40 submittal calls for a two-step process with ASTM F656 primer and ASTM D2564 cement.
- Never test PVC with compressed air or gas: Charlotte Pipe warns it "can result in explosive failures".
3. Will these two connect?
1/2" Copper L (0.625" OD) and 1/2" PEX (0.625" OD) have the same outside diameter (both are copper tube size). A 1/2" push-fit coupling listed to ASSE 1061 for both materials can join them directly; the Plastics Pipe Institute notes ASSE 1061 covers push-fit fittings up to 2 inches for PEX, Type K, L and M copper, CPVC and PE-RT. Check the fitting's label for both materials.
4. Full chart
| Nominal | OD (in) | ID (in) | Wall (in) | psi at 73°F |
|---|---|---|---|---|
| 1/2" | 0.840 | 0.622 | 0.109 | 600 |
| 3/4" | 1.050 | 0.824 | 0.113 | 480 |
| 1" | 1.315 | 1.049 | 0.133 | 450 |
| 1-1/4" * | 1.660 | 1.380 | 0.140 | 370 |
| 1-1/2" * | 1.900 | 1.610 | 0.145 | 330 |
| 2" * | 2.375 | 2.067 | 0.154 | 280 |
| 2-1/2" | 2.875 | 2.469 | 0.203 | 300 |
| 3" * | 3.500 | 3.068 | 0.216 | 260 |
| 4" | 4.500 | 4.026 | 0.237 | 220 |
| 5" | 5.563 | 5.047 | 0.258 | 190 |
| 6" | 6.625 | 6.065 | 0.280 | 180 |
| 8" | 8.625 | 7.981 | 0.322 | 160 |
| 10" | 10.750 | 10.020 | 0.365 | 140 |
| 12" | 12.750 | 11.938 | 0.406 | 130 |
PVC Schedule 40 (white), ASTM D1785. Wall: minimum. Inside diameter = average OD minus two minimum walls. Real walls are at or above the minimum, so real pipe is the same or slightly smaller inside. * Charlotte Pipe dual-marks these sizes for pressure (ASTM D1785) and drain, waste and vent (ASTM D2665). Source tables are listed at the bottom of the page.
A 1/2-inch pipe is not 1/2 inch across. Measure yours to find what it is, look up its real outside and inside diameter, and check which fittings connect two different pipes.
Why 1/2-inch pipe is not 1/2 inch
Household pipe comes in two size systems, and the nominal size printed on it is a name in both.Iron pipe size (IPS) covers PVC Schedule 40 and 80 and steel pipe: the same nominal size has the same outside diameter whatever the material, so 1/2-inch PVC and 1/2-inch steel are both 0.840 inch outside.Copper tube size (CTS) covers copper Types K, L and M, PEX and CTS CPVC: the Copper Tube Handbook says the actual outside diameter is "always 1/8-inch larger than the standard size designation", and the Plastics Pipe Institute says the same of PEX. A 1/2-inch pipe from one system will not fit a 1/2-inch fitting from the other.
| Nominal | IPS outside (PVC, steel) | CTS outside (copper, PEX, CPVC) |
|---|---|---|
| 1/2" | 0.840" (21.3 mm) | 0.625" (15.9 mm) |
| 3/4" | 1.050" (26.7 mm) | 0.875" (22.2 mm) |
| 1" | 1.315" (33.4 mm) | 1.125" (28.6 mm) |
| 1-1/4" | 1.660" (42.2 mm) | 1.375" (34.9 mm) |
| 1-1/2" | 1.900" (48.3 mm) | 1.625" (41.3 mm) |
| 2" | 2.375" (60.3 mm) | 2.125" (54.0 mm) |
Measure with a string: the circumference table
Most people at a hardware store have no caliper. Wrap a string or a strip of paper once around the pipe, mark it, and lay it on a tape measure; the finder above divides by pi. These are the distances around the common sizes. Notice the near-collisions: 1/2-inch IPS and 3/4-inch CTS differ by about 1/8 inch around, so check what the pipe is made of.
| Nominal | Around IPS pipe (PVC, steel) | Around CTS pipe (copper, PEX, CPVC) |
|---|---|---|
| 1/2" | 2.64" | 1.96" |
| 3/4" | 3.30" | 2.75" |
| 1" | 4.13" | 3.53" |
| 1-1/4" | 5.22" | 4.32" |
| 1-1/2" | 5.97" | 5.11" |
| 2" | 7.46" | 6.68" |
Worked example. A string around a rigid white pipe measures 2 5/8 inches. 2.625 / 3.1416 = 0.836 inch outside. The closest white-or-gray plastic match is 1/2" iron pipe size (0.840"), so it is 1/2-inch PVC, Schedule 40 or 80 (the print on the pipe says which). With "Not sure" picked, the finder also lists 3/4" copper tube size (0.875"), which is why the material question is there.
Schedule 40 vs Schedule 80 PVC
Same outside diameter, thicker wall. Charlotte Pipe's 1/2-inch Schedule 40 (white) has a 0.109-inch minimum wall and a 600 psi maximum working pressure at 73°F; its 1/2-inch Schedule 80 (gray) has a 0.147-inch wall and is rated 850 psi. Because the outside is the same, both fit 1/2-inch socket fittings, and the thicker wall means Schedule 80 is smaller inside. Charlotte rates its Schedule 40 pressure pipe for systems at or below 140°F and warns never to test PVC with compressed air or gas.
Copper Type K, L and M
All three share an outside diameter at each size and differ in wall thickness: K is thickest, then L, then M (Copper Tube Handbook). The print color tells them apart: green for K, blue for L, red for M.
| 1/2" tube | Wall | Inside | Rated, drawn, 100°F |
|---|---|---|---|
| Type K (green) | 0.049" | 0.527" | 1534 psi |
| Type L (blue) | 0.040" | 0.545" | 1242 psi |
| Type M (red) | 0.028" | 0.569" | 850 psi |
Those are ratings for the tube. The handbook adds that "the lower of the ratings (tube, fitting or joint) will govern," and soldered joints have their own ratings (its Table 14.4a), which can be much lower: joints made with 50-50 tin-lead solder in sizes up to 1 inch are rated 200 psi at 100°F. That is a lead solder: the handbook notes the Safe Drinking Water Act bans solder with more than 0.2% lead in drinking-water systems.
Same nominal size, different inside: PEX vs copper
PEX has a thicker wall than copper at the same size, so less room inside. 1/2-inch PEX is 0.475 inch inside (Plastics Pipe Institute) against 0.545 inch for 1/2-inch Type L copper: about 24% less flow area. At 3/4 inch the gap is about 27% (0.671 vs 0.785 inch). That is one reason a plumber may size a PEX run differently from the copper it replaces; the finder's "same nominal size" table shows the comparison for any size. PEX also bends: PPI's minimum bend radius is six times the outside diameter unless the tubing maker says otherwise, about 3.8 inches for 1/2-inch tubing.
CTS CPVC matches copper and PEX
CPVC sold in copper tube size (CTS) matches copper and PEX: Charlotte Pipe's FlowGuard Gold 1/2-inch CTS pipe is 0.625 inch outside, the same as 1/2-inch copper and PEX, with a 400 psi rating at 73°F. So 1/2-inch CTS CPVC takes 1/2-inch CTS fittings, not 1/2-inch PVC fittings.
How this is calculated
There is little arithmetic here; most of the page is published tables. The finder does three small calculations and looks everything else up.
Finding your pipe
If you measured around the pipe, the finder divides by pi (3.1416) to get the outside diameter (OD); millimeters are divided by 25.4 to get inches. It then compares that OD with every size in the tables for the material you picked and lists the sizes within 0.03 inch (OD measured) or 0.05 inch (worked out from a string, which is looser). Measurements outside 0.2 to 13.5 inches OD are rejected as outside the tables. If two sizes are both within tolerance, you get both, and the material decides.
Worked example. A string around a white plastic pipe reads 2 5/8 inches, which is 2.625 inches. 2.625 / 3.1416 = 0.836 inch OD, which is 0.004 inch from the 1/2" iron pipe size table value of 0.840 inch, so it is 1/2-inch PVC.
Inside diameter, flow area and water volume
Copper and steel inside diameters are published. For PVC and CTS CPVC, which publish an OD and a minimum wall, the inside diameter is the OD minus two minimum walls, rounded to 0.001 inch, so real pipe (with walls at or above the minimum) is the same or slightly smaller inside. PEX inside diameters come from the PPI guide. "Less flow area" compares the circle area, pi / 4 x ID squared, of two pipes. "Water inside, per 10 feet" is that area x 120 inches / 231 cubic inches per US gallon. For 1/2-inch PEX against 1/2-inch Type L copper that is about 24% less area.
Where the numbers come from
- PVC Schedule 40 and 80 outside diameters, minimum walls and pressure ratings: Charlotte Pipe: PVC Schedule 40 DWV and Pressure Pipe, Product Data Sheet PVC-40-PE-PIPE-322 (effective March 17, 2022; checked Oct 8, 2026) and Charlotte Pipe: PVC Schedule 80 Pipe, Product Data Sheet PVC-80-PIPE-225 (effective February 13, 2025; checked Oct 8, 2026).
- Steel pipe sizes: Wheatland Tube: Standard Pipe brochure, Standard Pipe Schedule 40, ASTM A53 (checked Oct 8, 2026).
- Copper Types K, L and M dimensions and ratings: Copper Development Association: The Copper Tube Handbook, CDA Publication A4015-26/24 (PDF; checked Oct 8, 2026), and its tables 14.2 and 14.3 linked under the sources at the bottom of the page.
- PEX: Plastics Pipe Institute: PEX Plumbing Distribution Systems Design and Installation Guide, Third Edition (April 2026), Table 3.1 and chapters 3, 5 and 9 (checked Oct 8, 2026).
- CTS CPVC: Charlotte Pipe: FlowGuard Gold CPVC Copper Tube Size Pipe, Product Data Sheet CTS-PIPE-1018 (updated March 20, 2023; checked Oct 8, 2026).
What these tables leave out
- Pipe sizing for flow (how big a line a house needs). That depends on fixture counts, pressure and length under your plumbing code; ask a licensed plumber.
- Metric pipe, ABS, polybutylene, cast iron, galvanized pipe's threads and drain-only PVC types.
- Tolerances. Real pipe varies slightly from these averages and nominal figures; the standards set how much.
Questions people ask
What is the actual outside diameter of 1/2 inch PVC pipe?
0.840 inches (21.3 mm), for both Schedule 40 and Schedule 80. PVC Schedule 40 and 80 are iron pipe size, the same outside diameter as steel pipe of that nominal size. Schedule 80 has the thicker wall (0.147 inch minimum against 0.109 for Schedule 40, per Charlotte Pipe), so it is smaller inside.
Is 3/4 copper pipe 7/8 OD?
Yes. Copper water tube (Types K, L and M) is named 1/8 inch under its outside diameter, so 3/4 inch tube measures 0.875 inch (7/8) outside, and 1/2 inch tube measures 0.625 (5/8). PEX and CTS CPVC follow the same rule.
Is 5/8 bigger than 1/2 copper?
As plumbing tube sizes, yes: 5/8 inch Type L has a 0.750 inch outside diameter against 0.625 for 1/2 inch. The mix-up comes from air conditioning and refrigeration (ACR) tube, which the Copper Development Association says is named by its actual outside diameter: 5/8 inch ACR tube is the same outside size as 1/2 inch plumbing tube, and the handbook's fitting table pairs 1/2 inch fittings with both.
What is the difference between Type L and Type M copper?
Wall thickness. At 1/2 inch, Type L has a 0.040 inch wall and Type M 0.028, with the same 0.625 inch outside diameter, so they take the same fittings. The Copper Tube Handbook rates 1/2 inch drawn Type L at 1242 psi and Type M at 850 psi (100°F). Type L is printed in blue and Type M in red. The handbook lists both for domestic water service and distribution; it lists Type L, not Type M, for natural gas and LP gas. Your local plumbing code decides what is allowed where you live.
What schedule is PVC drain pipe?
Schedule 40 is the common one. Charlotte Pipe dual-marks its 1-1/4, 1-1/2, 2 and 3 inch Schedule 40 pipe for pressure (ASTM D1785) and for drain, waste and vent use (ASTM D2665). PVC sold only as drain pipe can be other types, so read the print on the pipe.
Does 1/2 inch PEX fit 1/2 inch copper fittings?
Not copper solder (sweat) fittings. The outside diameters match (0.625 inch), so push-fit fittings listed to ASSE 1061 can join them; the Plastics Pipe Institute notes that standard covers push-fit fittings up to 2 inches for PEX, copper Types K, L and M, CPVC and PE-RT. Check that the fitting's label names both. Crimp, press and expansion PEX fittings work differently from copper solder fittings, and PPI says to solder copper transition fittings first and let them cool before connecting PEX.
How do I tell PVC from steel pipe of the same size?
You cannot by size alone: 1/2 inch PVC Schedule 40 and 1/2 inch Schedule 40 steel are both 0.840 inch outside with the same 0.109 inch wall. A magnet sticks to steel (black or galvanized) and not to PVC.
Where these tables come from
- Charlotte Pipe: PVC Schedule 40 DWV and Pressure Pipe, Product Data Sheet PVC-40-PE-PIPE-322 (effective March 17, 2022; checked Oct 8, 2026)
- Charlotte Pipe: PVC Schedule 80 Pipe, Product Data Sheet PVC-80-PIPE-225 (effective February 13, 2025; checked Oct 8, 2026)
- Charlotte Pipe: Submittal for PVC Schedule 40 Pressure Pipe, FO-SUB-PVC-40-PIPE (5-15-20) (socket dimensions for belled-end pipe; checked Oct 8, 2026)
- Charlotte Pipe: FlowGuard Gold CPVC Copper Tube Size Pipe, Product Data Sheet CTS-PIPE-1018 (updated March 20, 2023; checked Oct 8, 2026)
- Wheatland Tube: Standard Pipe brochure, Standard Pipe Schedule 40, ASTM A53 (checked Oct 8, 2026)
- Copper Development Association: The Copper Tube Handbook, CDA Publication A4015-26/24 (PDF; checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.1, tube types, color codes and standards (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.2a, Type K dimensions (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.2b, Type L dimensions (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.2c, Type M dimensions (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.3a, rated working pressures, Type K (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.3b, rated working pressures, Type L (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.3c, rated working pressures, Type M (checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.4a, pressure-temperature ratings of soldered and brazed joints (in the handbook PDF; checked Oct 8, 2026)
- Copper Development Association: Copper Tube Handbook Table 14.9, solder joint ends for wrought pressure fittings (checked Oct 8, 2026)
- Plastics Pipe Institute: PEX Plumbing Distribution Systems Design and Installation Guide, Third Edition (April 2026), Table 3.1 and chapters 3, 5 and 9 (checked Oct 8, 2026)
Related calculators
- Water Heater Replacement Cost Calculator: Tank or tankless, gas or electric: the installed price range, plus a check on whether a quote is fair and whether a flush would do instead.
- Sewer Line Repair and Replacement Cost Calculator: Spot repair, trenchless lining or full replacement: price by length, depth and method, and how to read a sewer quote.
- Water Damage Restoration Cost Estimator: Clean, gray or black water, by square footage: what drying and repair usually cost and what insurance tends to cover.
- Mold Remediation Cost Estimator: Price by affected area and location in the house, plus when testing is worth paying for.